LED Display & Module Troubleshooting
This guide covers the most frequent failure points in LED systems. Follow the symptom → cause → solution flow for rapid resolution.
| Symptom | Possible Cause | Diagnostic Step | Action Required |
|---|---|---|---|
| Entire screen is black (no power) | Power supply failure, tripped breaker, loose AC input | Check PSU indicator lights; measure input voltage with multimeter | Replace faulty PSU; ensure 220V ±10%; verify grounding |
| Partial blackout (large dark area) | Failed receiving card, broken power cable to module row | Inspect power distribution at affected zone; test with spare receiving card | Replace receiving card or repair/replace power daisy-chain |
| Flickering or unstable brightness | Unstable DC output, poor grounding, aging LEDs | Measure PSU ripple with oscilloscope; check earth resistance (<4Ω) | Install regulated PSU; re-ground system; replace aged modules |
| Color distortion / wrong colors | Data signal error, IC malfunction, incorrect calibration | Run “single-point test” in control software; inspect flat cable integrity | Re-seat or replace ribbon cable; recalibrate color; replace faulty IC |
| “Caterpillar” lines (vertical color streaks) | Driver IC leakage, shorted row transistor, ESD damage | Locate streak origin; check for burnt smell or swollen capacitors | Replace damaged module; use anti-static wrist strap during handling |
| Screen shows content but software can’t connect | Network issue, IP conflict, sending card failure | Ping control card IP; verify network cable; check firewall settings | Replace Cat6 cable; assign static IP; swap sending card if needed |
| Maintenance Area | Best Practice | Frequency |
|---|---|---|
| Environment | Keep ambient temperature 10–30°C (indoor); humidity <85% RH | Continuous monitoring |
| Power System | Use dedicated circuit with surge protection; ground resistance ≤4Ω | Quarterly inspection |
| Cleaning | Wipe with soft brush or microfiber cloth; no alcohol or solvents | Monthly (outdoor), Quarterly (indoor) |
| Software | Backup configuration monthly; update firmware annually | As scheduled |
| Idle Displays | Power on for 30 minutes every month to prevent moisture buildup | Monthly |

Explore More from Queendom Lamp